Sign In | Join Free | My isp.org.cn |
|
Brand Name : Tankii
Model Number : K
Certification : ISO9001
Place of Origin : China Mainland
MOQ : Negotiable
Price : Negotiation
Payment Terms : T/T, Paypal, Western Union, MoneyGram,
Supply Ability : 1000Ton per year
Delivery Time : 5~20 days as per order qty
Packaging Details : Standard exoprt package in carton box or wooden case
TC wire Standard : International
Main Application : thermocouple sensor, MI cable
EMF Tolerance : IEC 60584 class 1 or class 2
Wire size : Tailor made
lead time : 5~10 days after getting the payment
Item : IEC 60584 Class One 0.1mm To 12mm Thermocouple Wire Types K /J /E/T
Types : K, J, T, N,E
Wire pack : On bobbin, carton case, wooden case
IEC 60584 Class One 0.1mm To 12mm Thermocouple Wire Types K /J /E/T
The simplest thermocouple is made using a bare wire configuration, that is two thermoelements joined at one end and directly exposed to the atmosphere of the operating environment.
Thermocouple wire allows temperatures to be measured electronically. A typical thermocouple construction consists of a pair of dissimilar metals that are electrically joined together at the sensing point and connected to a voltage measuring instrument at the other end. When one junction is hotter than the other, a thermal “electromotive” force (in millivolts) is produced that is roughly proportional to the difference in temperature between the hot and cold junctions.
IEC 60584 Class One 0.1mm To 12mm Thermocouple Wire Types K /J /E/T
Shanghai Tankii Thermocouple wire's Characteristics:
The thermocouple wires have excellent performance and are extensively used in the temperature measurement and control in different fields, such as metallurgy, chemical industry, petroleum industry, machinery-electric industry, energy industry, agriculture and military industry.
Tankii products conform to the standards of IEC584 -1 and 2.
Thermocouple type and index | Measurement Range ℃ | |
Type | Index | |
| B | 600~1700 |
| R | 0~1600 |
| S | 0~1600 |
| K | -200~1300 |
| E | -200~900 |
| J | -40~750 |
| T | -200~350 |
| N | -200~1300 |
The allowable grade and Tolerance are obtained at 0℃
Thermocouple | Grade | Temperature range | Allowable Tolerance /℃ |
Type B | Ⅱ | 600~1700 | ±0.25% t |
Ⅲ | 600~800 | ±4 | |
800~1700 | ±0.5%t | ||
Type R(S) | Ⅰ | 0~1100 | ±1 |
1100~1600 | ±[1+(t-1100) ×0.3%] | ||
Ⅱ | 0~600 | ±1.5 | |
600~1600 | ±0.25% t | ||
Type K and Type N | Ⅰ | -40~1100 | ±1.5℃ or ±0.4%t |
Ⅱ | -40~1300 | ±2.5℃ or ±0.75%t | |
Ⅲ | -200~40 | ±2.5℃ or ±1.5%t | |
Type E | Ⅰ | -40~1100 | ±1.5℃ or ±0.4%t |
Ⅱ | -40~1300 | ±2.5℃ or ±0.75%t | |
Ⅲ | -200~40 | ±2.5℃ or ±1.5%t | |
Type J | Ⅰ | -40~750 | ±1.5℃ or ±0.4%t |
Ⅱ | -40~750 | ±2.5℃ or ±0.75%t | |
Type T | Ⅰ | -40~350 | ±0.5℃ or ±0.4%t |
Ⅱ | -40~350 | ±1.0℃ or ±0.75%t | |
Ⅲ | -200~40 | ±1.0℃ or ±1.5%t |
Product packing details:
![]() |
IEC 60584 0.1mm Thermocouple Compensating Wire Types J Images |